Skip to content
EffectiV

SelectiV · Air distribution design software

Don’t just design air distribution.See it perform.

The next generation of HVAC air distribution design is here. And it’s free.

What if you could see how air moves through a room before it’s built? Compare heating and cooling performance, explore different diffuser configurations, and let intelligent Auto-Design find the optimal solution?

SelectiV combines proven diffuser performance data with advanced airflow physics to take room air distribution design beyond catalogue tables and traditional selection methods.

Stop guessing. Start engineering the room.

AHR Expo 2027 Innovation Awards finalist

2027 AHR Expo Innovation Awards · Software category finalist

selectiv.design Side view
SelectiV top view of four KOBE jet diffusers in cooling and heating
SelectiV front view of the KOBE jets, with the occupied zone
SelectiV side view of a jet in cooling and heating, with the 6 ft occupant height
SelectiV 3D view of the KOBE jets in cooling and heating
Cooling Heating

Room First. By design.

The room changes everything.

For decades, engineers have selected diffusers based primarily on catalogue performance data: throw, pressure drop, airflow and noise.

But a diffuser doesn’t operate in a catalogue. It operates in a room.

SelectiV brings the room into the design process. Instead of evaluating diffusers in isolation, engineers visualize how air distribution performs within the actual space, for more informed decisions about occupant comfort, airflow patterns and system performance.

The objective isn’t simply to select a diffuser.
It’s to engineer the right conditions for the people inside the room.

The Room First philosophy
Meeting room with performance datasheets taped to the ceiling where the diffusers should be
What often gets designed: a datasheet in the ceiling.

What SelectiV accounts for in its airflow computations

  • 01 Ceiling height
  • 02 Room geometry
  • 03 Heating and cooling temperatures
  • 04 Airflow rates
  • 05 Adjacent walls
  • 06 Competing air jets

Visualize airflow

See the invisible. Before you build.

Air is invisible. Its impact shouldn’t be. Create your room in an intuitive 3D environment, position your diffusers, define operating conditions and visualize predicted airflow throughout the space.

Airflow velocity fields · TopAirflow velocity fields · FrontAirflow velocity fields · Side
20150 fpm
Heating and cooling · Cooling · 55 °F Heating and cooling · Heating · 90 °F Cooling · 55 °F Heating · 90 °F

3D preview: an approximate reconstruction from the top, front and side views.

1 Ceiling attachment
2 Jets meet
3 Windows
4 Floor jet
5 Occupied zone

Occupant-zone performance: evaluate predicted air velocities where comfort matters most. Don’t just select air terminals. Understand how they work together.

Auto-Design

What if your best design isn’t the first one you think of?

Traditional air distribution design relies heavily on experience, judgment and time-consuming manual comparisons. Let Auto-Design explore the possibilities for you.

  1. 01

    Describe the room and the goal

    Total airflow, ceiling type, mounting, diffuser shape, air curtains at the windows: Auto-Design suggests families of layouts suited to the room.

    Describe the room and the goal
  2. 02

    Compare thousands of solutions

    By analyzing thousands to hundreds of thousands of combinations, Auto-Design evaluates diffuser sizes, configurations, quantities and locations, and ranks the results with throw, NC and perceived NC.

    Compare thousands of solutions
  3. 03

    Apply it in the room

    The chosen solution is placed in the 3D room, ready to visualize, refine and document. Less trial and error. More intelligent design.

    Apply it in the room

Not CFD. Built for everyday design.

The power of physics. The speed of selection.

Catalogue tables provide useful product data. CFD delivers detailed numerical airflow analysis. But most everyday design decisions need something in between.

Catalogue tables

Useful product data, evaluated outside the room.

  • Fast
  • Isolated

SelectiV

Manufacturer performance data, established air distribution principles and physics-informed calculations: room-level airflow prediction in a fast, intuitive environment.

  • Minutes
  • Room-level
  • Free

Verified CFD

Detailed numerical analysis for critical applications, performed by EffectiV.

  • Deep analysis
  • ASHRAE 62.1

No complex CFD setup. No specialized simulation expertise. No waiting hours for routine design comparisons.

Explore Verified CFD

SelectiV is a physics-informed air distribution design tool, not a CFD solver. Its predictions are subject to the assumptions and limitations of its modeling methods.

Beyond individual diffusers

From air terminals to complete architectural air distribution.

Continuous linear slot diffusers

Design uninterrupted linear runs with active and inactive sections. SelectiV helps configure the layout and automatically determines the individual components required.

Architectural perforated duct diffusers

Design complete BREEZ duct layouts in 3D, with sections, elbows, reducers and branches. Auto-Design can evaluate tens or hundreds of thousands of perforation-pattern candidates for each duct section.

Architectural duct diffusers

Complex air distribution systems. Remarkably intuitive design.

Engineered for real operating conditions

One room. Multiple conditions. One optimized design.

A room doesn’t operate under a single set of conditions, and neither should its air distribution design. With SelectiV’s VAV and CAV capabilities, engineers define airflow rates and supply temperatures for heating and cooling, and Auto-Design considers them when evaluating configurations.

  • Minimum airflow
  • Maximum airflow
  • Cooling
  • Heating
  • VAV
  • CAV

A great design should perform beyond a single operating point.

Cooling
Heating

The details that matter

Engineering insight, without the complexity.

Airflow performance

Predicted throw, spread and air velocity under specified operating conditions.

Thermal behaviour

How heating and cooling influence jet trajectories, air mixing and the occupied zone.

Acoustic performance

Individual diffuser NC and estimated room-level perceived NC.

Pressure drop

Static pressure information to support product selection and system design.

Engineering documentation

Detailed PDF reports of selections, room configuration, operating conditions and predicted performance.

Built for teams

Compare, rate, discuss.

Save alternate designs for every room, compare their airflow side by side, rate them, and leave pinned notes right in the 3D room.

AHR Expo 2027 Innovation Awards finalist

Award-recognized innovation

Redefining what’s possible in HVAC design.

SelectiV’s recognition among the finalists in the Software category reflects a new approach to one of HVAC engineering’s most fundamental challenges: understanding air distribution performance before installation. And we’re only getting started.

Watch SelectiV in action.

Your next design starts here

Better air distribution is now within reach.

No expensive licenses. No complex installation. No steep learning curve. Just powerful, browser-based design tools, free for HVAC engineers and designers.

Design the room. Explore the possibilities. See the performance.

Room First. By EffectiV.